BB Unix Network Monitor - Message

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: {bb} bb-prtdiag-4_5.tar.gz posted to deadcat.



Craig,
Don't know if someone already sent this to you or not (v240 prtdiag -v).  
Jamie Rogers.



snip
######
System Configuration: Sun Microsystems  sun4u Sun Fire V240
System clock frequency: 167 MHZ
Memory size: 4GB        

==================================== CPUs
====================================
                      E$          CPU     CPU       Temperature         Fan
       CPU  Freq      Size        Impl.   Mask     Die    Ambient   Speed
Unit
       ---  --------  ----------  ------  ----  --------  --------  -----
----
     MB/P0  1002 MHz  1MB         US-IIIi  2.4       -        -    
     MB/P1  1002 MHz  1MB         US-IIIi  2.4       -        -    

================================= IO Devices
=================================
     Bus   Freq
Brd  Type  MHz   Slot        Name                          Model
---  ----  ----  ----------  ----------------------------
--------------------
 0   pci    66           MB  pci108e,1648 (network)

 0   pci    66           MB  pci108e,1648 (network)

 0   pci    33           MB  isa/su (serial)

 0   pci    33           MB  isa/su (serial)

 0   pci    33           MB  pci10b9,5229 (ide)

 0   pci    66           MB  scsi-pci1000,21 (scsi-2)

 0   pci    66           MB  scsi-pci1000,21 (scsi-2)

 0   pci    66           MB  pci108e,1648 (network)

 0   pci    66           MB  pci108e,1648 (network)

 0   pci    33            7  isa/rmc-comm-rmc_comm (seria+


============================ Memory Configuration
============================
Segment Table:
-----------------------------------------------------------------------
Base Address       Size       Interleave Factor  Contains
-----------------------------------------------------------------------
0x0                2GB               4           BankIDs 0,1,2,3
0x1000000000       2GB               2           BankIDs 16,17

Bank Table:
-----------------------------------------------------------
           Physical Location
ID       ControllerID  GroupID   Size       Interleave Way
-----------------------------------------------------------
0        0             0         512MB           0,1,2,3
1        0             1         512MB           
2        0             1         512MB           
3        0             0         512MB           
16       1             0         1GB             0,1
17       1             0         1GB             

Memory Module Groups:
--------------------------------------------------
ControllerID   GroupID  Labels
--------------------------------------------------
0              0        MB/P0/B0/D0,MB/P0/B0/D1
0              1        MB/P0/B1/D0,MB/P0/B1/D1

Memory Module Groups:
--------------------------------------------------
ControllerID   GroupID  Labels
--------------------------------------------------
1              0        MB/P1/B0/D0,MB/P1/B0/D1

============================ Environmental Status
============================
Fan Speeds:
-----------------------------------------
Location       Sensor      Status   Speed
-----------------------------------------
MB/P0/F0       RS          okay     16463 rpm         
MB/P0/F1       RS          okay     16463 rpm         
MB/P1/F0       RS          okay     17307 rpm         
MB/P1/F1       RS          okay     16463 rpm         
F0             RS          okay     6081 rpm         
F1             RS          okay     6250 rpm         
F2             RS          okay     6428 rpm         
PS0            FF_FAN      okay         
PS1            FF_FAN      okay         
---------------------------------
Keyswitch:
---------------------------------
Location       Keyswitch   State
---------------------------------
--------------------------------------------------
Led State:
--------------------------------------------------
Location   Led                   State       Color
--------------------------------------------------
MB         ACT                   on          green           
MB         SERVICE               off         amber           
MB         LOCATE                off         white           
PS0        ACT                   on          green           
PS0        SERVICE               off         amber           
PS0        OK2RM                 off         blue            
PS1        ACT                   on          green           
PS1        SERVICE               off         amber           
PS1        OK2RM                 off         blue            
HDD0       SERVICE               off         amber           
HDD0       OK2RM                 off         blue            
HDD1       SERVICE               off         amber           
HDD1       OK2RM                 off         blue            
HDD2       SERVICE               off         amber           
HDD2       OK2RM                 off         blue            
HDD3       SERVICE               off         amber           
HDD3       OK2RM                 off         blue            
-------------------------------------------------------------------
Temperature sensors:
-------------------------------------------------------------------
Location       Sensor      Temperature  Lo LoWarn HiWarn  Hi Status
-------------------------------------------------------------------
MB             T_ENC           25C     -3C    5C   40C   48C okay
MB/P0          T_CORE          51C     -     -    110C  115C okay
MB/P1          T_CORE          51C     -     -    110C  115C okay
PS0            FF_OT           -       -     -     -     -   okay
PS1            FF_OT           -       -     -     -     -   okay
------------------------------------------------------------------------
Voltage sensors:
------------------------------------------------------------------------
Location   Sensor        Voltage  Lo     LoWarn  HiWarn   Hi    Status
------------------------------------------------------------------------
MB         V_VTT          1.30V       -     1.17V   1.43V     -   okay
MB         V_GBE_+2V5     2.51V       -     2.25V   2.75V     -   okay
MB         V_GBE_CORE     1.21V       -     1.08V   1.32V     -   okay
MB         V_VCCTM        2.53V       -     2.25V   2.75V     -   okay
MB         V_+2V5         2.60V       -     2.34V   2.86V     -   okay
MB         V_+1V5         1.51V       -     1.35V   1.65V     -   okay
MB/BAT     V_BAT          2.95V       -     2.70V     -       -   okay
MB/P0      V_CORE         1.45V       -     1.26V   1.54V     -   okay
MB/P1      V_CORE         1.46V       -     1.26V   1.54V     -   okay
PS0        FF_UV            -         -       -       -       -   okay
PS0        FF_OV            -         -       -       -       -   okay
PS0        P_PWR            -         -       -       -       -   okay
PS1        FF_UV            -         -       -       -       -   okay
PS1        FF_OV            -         -       -       -       -   okay
PS1        P_PWR            -         -       -       -       -   okay
----------------------------------------------------------------------
Current sensors:
----------------------------------------------------------------------
Location   Sensor      Current    Lo     LoWarn  HiWarn   Hi    Status
----------------------------------------------------------------------
MB         FF_SCSI      -         -       -       -       -   okay
PS0        FF_OC        -         -       -       -       -   okay
PS1        FF_OC        -         -       -       -       -   okay

======== FRU Status =========
-------------------------
Fru Operational Status:
-------------------------
Location        Status   
-------------------------
MB/SC           okay
PS0             okay
HDD0            present
PS1             okay

================================ HW Revisions
================================
ASIC Revisions:
---------------
pci: Rev 4
pci: Rev 4
pci: Rev 4
pci: Rev 4

System PROM revisions:
----------------------
OBP 4.11.4 2003/07/23 08:04 Sun Fire V210/V240,Netra 240
OBDIAG 4.11.4 2003/07/23 08:05  


######
snip






-----Original Message-----
From: Craig Cook [mailto:craig@cookitservices.com]
Sent: Friday, February 25, 2005 10:03 AM
To: bb@bb4.com
Subject: Re: {bb} bb-prtdiag-4_5.tar.gz posted to deadcat.


This is certainly appreciated!

I made one small change for the voltage checks
From:
BAD_VOL=`$GREP "V_" $PRTFILE |
To:
BAD_VOL=`$EGREP "V_|P_|FF_" $PRTFILE |

Also noticed this section is not checked... should it be?

Led State:
--------------------------------------------------
Location   Led                   State       Color
--------------------------------------------------
SYS        ACT                   on          green
SYS        SERVICE               off         amber
SYS        LOCATE                off         white
PS0        POK                   on          green
PS0        STBY                  on          green
PS0        SERVICE               off         amber
PS0        OK2RM                 off         blue
PS1        POK                   on          green
PS1        STBY                  on          green
PS1        SERVICE               off         amber
PS1        OK2RM                 off         blue
HDD0       SERVICE               off         amber
HDD0       OK2RM                 off         blue
HDD1       SERVICE               off         amber
HDD1       OK2RM                 off         blue
HDD2       SERVICE               off         amber
HDD2       OK2RM                 off         blue
HDD3       SERVICE               off         amber
HDD3       OK2RM                 off         blue

Also, can someone please send me a copy of V210 output to add to the test
data?

Thanks

Craig Cook
--
Big Brother Consulting and Training Services
www.cookitservices.com

--
=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-==-=-=-=-=-=-=-=-=-=-=-=
To unsubscribe from this list, or to subscribe to the bb-digest list
send e-mail to mailto:majordomo@bb4.com with unsubscribe bb -and/or-
subscribe bb-digest in the BODY of the message.
--
=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-==-=-=-=-=-=-=-=-=-=-=-=
To unsubscribe from this list, or to subscribe to the bb-digest list
send e-mail to mailto:majordomo@bb4.com with unsubscribe bb -and/or-
subscribe bb-digest in the BODY of the message.


Home | Main Index | Thread Index